ZXMW PR10 S200 (Published on:7/21/2014 4:44:54 AM)

Hi

I am having a problem  with  poor perfomance on the Microwave link, S200 equipment

The link is intermittent 

checked current and history of  RSL's on both sites and they look good as planned -43db 

Background Block Errors, Errored Second and Severely Errored second are very high as a result the link is intermittent.

I checked IF cable connectors and they look fine.

i am not too sure what is causing the errors on the link, can i get support please



thanks  

regards 

Samuel





Common member
Samuel001850110

Common member
Score::17
Registered on:2014-06-04
Reply:ZXMW PR10 S200 (Published on:7/22/2014 4:01:26 AM)

hi


RSL are normal according to design


can you please give me the email address  where i can send  the logs , performance and history of the site.



thanks 


regards

Samue





Common member
Samuel001850110

Common member
Score::17
Registered on:2014-06-04
Reply:ZXMW PR10 S200 (Published on:7/21/2014 10:43:24 PM)
thanks, i will do that and let you know



ZTE engineer
10079490

ZTE engineer
Score::2
Registered on:2009-01-22
Reply:ZXMW PR10 S200 (Published on:7/21/2014 10:56:09 AM)

Dear Samuel:

First, you should check the design file. I think the -43dB is lower than design.

you need check design result such as: bandwidth/modulation/frequency/tx power/rsl ...

If the RSL is normal according to the design file(PL4), please collect the history alarm/history log/performance data/setting data ... to us by email.

we will analyse the data and give suggestion to you。





ZTE engineer
10078423

ZTE engineer
Score::596
Registered on:2011-12-26
Reply:ZXMW PR10 S200 (Published on:7/21/2014 10:32:12 AM)

Hi  My friend

    It maybe caused by frequency interference. You can mute one end of the link to check whether the opponent site can still receive RSL. 